SysPhS-1.1 (and MDSysML/Cameo 19SP3 SysPhSLibrary): Use of RealSignalInElement for Real.Routing.Switch::u2 inconsistent with BooleanInput of control port Modelica.Blocks.Logical.Switch::u2

This page identifies a possible issue, inconsistency, concern, error, or bug!
One of the ways Webel IT Australia helps promote tools, technologies, and languages is by donating a lot of time identifying, tracking, and reporting potential issues, in order to help vendors and developers improve the tools and technologies. In some cases, we also offer workarounds and advice for users. All issues tracked on our public site are offered most constructively and with sincerest gratitude to the tool vendors and technology developers.
DISCLAIMER: Vendors do not officially endorse issue analysis by Webel IT Australia.
Icon class
icon_class
far fa-sticky-note
icon_class_computed
far fa-sticky-note
Note kind
Specification keywords
Modelica keywords
SysPhS Keywords
Keywords
Click on the image to view it full size

A Modelica.Blocks.Logical.Switch has a control port u2 of type BooleanInput.

The MagicDraw SysML Plugin and Magic Cyber-Systems Engineer ® (Cameo Systems Modeler®) library for SysPhS has u2 : RealSignalInElement [1] (which the spec table on p.60 implies).

In Wolfram SystemModeler it is not even permitted to connect from a RealOutput to a BooleanInput port.