CoolProp: Mathematica wrapper: Psychrometrics (humid air): When obtaining the dew point temperature 'Tdp' at the pressure 'P', humidity ratio 'W', and dry bulb temperature 'Tdb', the 'Tdb' value will be "ignored" but MUST be within a sensible range!

Webel IT Australia promotes the amazing Mathematica tool and the powerful Wolfram Language and offers professional Mathematica services for computational computing and data analysis. Our Mathematica tips, issue tracking, and wishlist is offered here most constructively to help improve the tool and language and support the Mathematica user community.
DISCLAIMER: Wolfram Research does not officially endorse analysis by Webel IT Australia.
Icon class
icon_class
far fa-sticky-note
icon_class_computed
far fa-sticky-note
Note kind
Policy level
Keywords
The dew point temperature (key 'Tdp' in CoolProp) only strictly depends on the pressure 'P' and the humidity ratio 'W'. But the CoolProp wrapper API for Mathematica requires a 3rd input argument. If the dry bulb temperature 'Tdb' is used, it will be essentially "ignored" (the value does not affect the result), however it MUST be within a sensible range compatible with the psychrometric chart, or the CoolProp wrapper returns Infinity.